Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 359
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2019  |  Volume : 16  |  Issue : 6  |  Page : 389-397

Effect of Er:YAG laser cavity preparation on the bond strength of 2-hydroxyethyl methacrylate-free and 2-hydroxyethyl methacrylate-rich self-etch adhesive systems: An in vitro study


1 Department of Conservative Dentistry and Endodontics, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, Rajasthan, India
2 Department of Conservative Dentistry and Endodontics, Rajasthan Dental College and Hospital, Jaipur, Rajasthan, India
3 Department of Oral Pathology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, Rajasthan, India

Correspondence Address:
Dr. Kanu Jain
Department of Oral Pathology, Maharaja Ganga Singh Dental College and Research Centre, 11 L.N.P Hanumangarh Road, Near Ricco, Sri Ganganagar - 335 001, Rajasthan
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.270789

Rights and Permissions

Background: Despite many advantages of lasers and reduction of the risk of surface bonding errors with newer self-etch systems, they have not been thoroughly researched. This study was done to evaluate the effect of Er:YAG laser cavity preparation on the microtensile bond strength of 2-hydroxyethyl methacrylate (HEMA)-rich and HEMA-free one-step self-etch adhesive systems. Materials and Methods: In this in vitro study, eighty freshly extracted human premolars were collected. Cavities were prepared in 40 teeth with carbide bur (Group 1) and in other 40 teeth with Er:YAG LASER (490 mJ and 15 Hz) (Group 2). Subgroups of twenty teeth each were made according to the adhesive systems used. After placement of restoration, the mean values of the bond strength were calculated using universal testing machine. Data were then tabulated and analyzed using descriptive statistics (Significant at P < 0.05). Results: The overall microtensile bonding strength was higher when the cavities were prepared with bur compared to those with Er:YAG laser. Mean bond strengths of single-bottle self-etching seventh-generation dentin bonding agents to bur-prepared cavities were higher than those to laser-prepared cavities irrespective of the adhesive system (P = 0.01). No statistically significant difference was observed between HEMA-free and HEMA-rich self-etch adhesive systems. Conclusion: The effect of Er:YAG laser for cavity preparation did not show improved performance when evaluated using microtensile bond strength with seventh-generation bonding agents, Adper Easy One and G-Bond. More studies are required to assess the effect of lasers.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed73    
    Printed2    
    Emailed0    
    PDF Downloaded12    
    Comments [Add]    

Recommend this journal