1 Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
2 Department of Prosthodontics, Faculty of Dentistry, Northern Khorasan University of Medical Sciences, Bojnourd, Iran
3 Department of Prosthodontics, Faculty of Dentistry, Semnan University of Medical Sciences, Semnan, Iran

Correspondence Address:
Dr. Atefe Baghbani
Department of Prosthodontics, School of Dentistry, Northern Khorasan University of Medical Sciences,Bojnourd
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.276233

Rights and Permissions

Background: The type of housing retaining material may affect the bond strength of the housing to denture base resin. The aim of this in vitro study was to evaluate the bond strength of locator housing attached to polymethyl methacrylate (PMMA) denture base resin secured with different retaining materials. Materials and Methods: In this in vitro study Forty-four PMMA blocks (10 mm × 15 mm × 15 mm) were prepared with a central cylindrical canal inside to allow the insertion of locator housings. The prepared specimens were then randomly divided into four groups (n = 11). Each group received one of the following retaining materials for housing insertion: Auto-polymerized acrylic resin (APAR), auto-polymerized composite resin (Quick up), application of alloy primer on titanium housing plus Quick up (AL-Quick), and heat-polymerized acrylic resin (HPAR). The specimens were thermocycled 5000 times between 5°C and 55°C, followed by 1000 cycles of vertical insertion separation on the locator abutment. A push-out force was applied on the flat back surface of the housing after which the failure and shear bond strength values were calculated. The data were analyzed using one way-ANOVA and Games-Howell test (α = 0.05). Results: HPAR group had significantly higher shear bond strength values compared to the other groups (P < 0.05). No significant differences were found among the other remaining material groups (P > 0.05). Conclusion: Inserting of locator housing using HPAR resulted in higher bond strength between housing and denture base resin. The application of alloy primer did not improve the bond strength of locator housing which was retained with “Quick up”.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed399    
    Printed24    
    Emailed0    
    PDF Downloaded84    
    Comments [Add]    

Recommend this journal