Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 322
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 17  |  Issue : 5  |  Page : 326-337

Effects of different stretching extents, morphologies, and brands on initial force and force decay of orthodontic elastomeric chains: An in vitro study


1 Department of Orthodontics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
2 Dentist in Private Practice, Tehran, Iran

Correspondence Address:
Dr. Sara Mahboobi
Department of Orthodontics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.294331

Rights and Permissions

Background: Elastomeric chains are of clinical importance to orthodontics. Therefore, their behavior should be assessed under different conditions. Some of their critical aspects remain unstudied (including effects of different elongations and chain forms on their force properties). Therefore, we aimed to assess these factors. Materials and Methods: This in vitro study was performed on 540 observations: first, 90 chains (10 specimens per subgroup of three brands [American Orthodontics, Ortho Technology (OT), and G&H], each from three chain types [closed, short, and long]) were stretched for three extents (40%, 60%, and 100%) and their forces were measured using a universal testing machine. Afterward, 270 new chains of the same brands/types were stretched for the same extents by installing them onto pairs of pins with different interpin distances. Plates holding pins/chains were incubated in artificial saliva at 37°C for 4 weeks. Afterward, their forces were measured and analyzed using partial correlation coefficient, three-way analysis of variance (ANOVA), Tukey, Student's t, and Mann–Whitney tests (α = 0.001). Results: Forces degraded significantly from an overall mean of 3.97 ± 0.97 N to 1.29 ± 0.39 N after 4 weeks (all P = 0.000, t-test/Mann–Whitney). ANOVA showed highly significant differences among brands, types, and elongations, in terms of “initial force, force decay, and residual force” (all P = 0.000). Almost all post hoc pairwise comparisons were significant (Tukey P = 0.000). There was a strong positive correlation between elongation extent and force loss (r = 0.846, P = 0.000). Conclusion: OT might be the most preferable brand. Closed chains might usually show better results, especially in OT chains. Instead of using chains half of the size of the space (to elongate for 100%), longer chains should be used to stretch for lesser extents.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1053    
    Printed28    
    Emailed0    
    PDF Downloaded123    
    Comments [Add]    

Recommend this journal