Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 884
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 17  |  Issue : 6  |  Page : 439-446

Evaluation of reverse torque values and failure loads of three different abutment designs with internal connections


Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

Correspondence Address:
Dr. Azam Sadat Mostafavi
Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, North Kargar Ave, Tehran
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.302891

Rights and Permissions

Background: High percentage of biomechanical complications such as screw loosening in dental implants can be related to implant–abutment (I/A) connection properties which affect the behavior of implant assembly against functional loads in the oral cavity. The aims of the present study were to compare the reverse torque values (RTVs) and failure loads of three abutment types with internal Morse taper connection. Materials and Methods: In this experimental in vitro study, eighteen implants (4.5 mm × 10 mm bone level implants, Implantium, Dentium Co, Seoul, South Korea) were divided into three groups with different abutments: two-piece (TP) abutment, one-piece (OP) abutment, and screw abutment (SA), mounted in stainless-steel blocks according to ISO 14801. After completion the torque/detorque protocol, a compressive load (1 mm/min) was applied at 30° off-axis until failure. Mean reverse torque/tightening torque (RT/TT) values and failure loads were analyzed with one-way ANOVA test and Tukey's honest significant difference (α = 0.05). Failure modes were evaluated by radiography and stereomicroscopy. Results: RT/TT values in the TP group were lower than those in other groups (P < 0.001). Highest failure loads were observed in SA group (P = 0.002). In radiographic evaluation, all specimens showed deformation in I/A interface. Conclusion: I/A connections with larger surface areas may lead to higher RTVs (e.g., OP and SA groups). Use of an additional screw and indexed area in TP group did not reduce the bending resistance under static loading.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed192    
    Printed8    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    

Recommend this journal